A.Product introduction

1.Design Theme&Concept

Theme: People oriented, life optimization, image building, individuality showing.

Concept: Principles of safety and reliability, advanced technology, economic rationality, energy saving, environmental protection and convenient maintenance.

 

2.Standards and regulations that the design complies with

1)The structure and safety performance of the luminaires should be based on:

General safety requirements and tests for luminaires”                GB7000.1-2007

Safety requirements of luminaires for road and street lighting”      GB7000.5-2005

“Lamp controlgear, part 1”                                                GB19510.1-2004

2)The optical performance of the luminaires should be based on:

“Standard for lighting design of urban road”                            CJJ45-2006

“Photometry of luminaires for street lighting”                           GB9468-1998

 

3.Product characteristics

Aluminum AL6063 stretch forming is adopted, anodic oxidation, higher level of corrosion-proof;

Integrated aluminum die-casting ADC12 is adopted at both sides, electrostatic spraying, solid and corrosion-proof;

Air convection active heat dissipation method is adopted to ensure the working temperature of the light source; the power supply is placed below with lower temperature;

Large built-in space, intelligent PLC, Zigbee, sensor and other modules can be equipped;

Various optical angles, including TYPE IIITYPE IVTYPE V,NEMA4NEMA6 etc;

Various installation methods are available, including rotating bracket, wall mounting, pole mounting, etc.

 

4.Applicable occasions

1) Suitable for city square lighting and high pole area lighting;

2Large-scale building projection lighting, long-distance lighting;

3) High-pole lighting for airports, highways and parks;

4)  Basketball courts, football fields, tennis fields, baseball fields and other places.

 

5.Structural features

1) Power supply- dual waterproof

 

Built in waterproof power supply + shell protection, being placed under the lamp body, low temperature, IP66 design, protection functions including short circuit / overload / overvoltage / overheating .

2)Special optical design mask

 

Teijin Optics PC, high-precision injection molding, high light transmittance, with anti-yellowing, anti-ultraviolet and other functions.

 

二.Specifications and parameters

1. Product Selection Form

Type

Model

LED quantity(PCS)

Rated power(W)

Luminous flux/(LM)

 

 

Black

 

ZHS-TG03-200W

288pcs

200

26000LM

ZHS-TG03-300W

480pcs

300

39000LM

ZHS-TG03-400W

576pcs

400

42000LM

ZHS-TG03-600W

960pcs

600

78000LM

ZHS-TG03-800W

1152pcs

800

104000LM

ZHS-TG03-1200W

1920pcs

1200

156000LM

 

2. Electrical parameters

Parameters

Minimum

Rating  

Maximum

Operating voltage

100V AC

220V AC

240V AC

Operating frequency

43Hz

50Hz

63Hz

Total power

±5%

Light source power

10%

Power factor

0.92

0.95

0.99

Power efficiency

86%

89%

92%

Constant current accuracy

2%

3%

5%

 

3.Optical parameters

Projects

Parameter value

Efficacy

130 Lm/W

Luminous flux

200W≥26000Lm,300W≥39000Lm,400W≥42000Lm,600W≥78000Lm,800W≥104000Lm,1200W≥156000Lm

Luminaire efficiency

90%

Color rendering index

≥80

Light-emitting angle

TYPE II,TYPE III,TYPE IV,TYPE V,NEMA4,NEMA6

Color difference

5 SDCM

Color temperature

暖白:3000K   正白:4000K  冷白:5000K

 

4.Operation parameters

Projects

Parameter value

Surface temperature

<65℃

Operating temperature

‐25℃—45℃

Storage temperature

‐40℃—85℃

Humidity adaptation

90%

Material composition

Al, special optical design mask, high and low temperature resistant and waterproof silicone sealing ring

Mean time between failures

30000 hrs

Protection grade

IP66

Installation

Rotating bracket mounting, ₵60pole mounting, wall mounting

Recommended pole height

15m-18m

 

5.  Light distribution curve

 

    TYPE类                           NEMA4-25度                 NEMA6-45度   

6.Isophot diagram

             NEMA4-25度参考

7.Dimensions

1200w-with anti-dazzle cover 

           

 

 

 

 

三、Product description

1. Instructions

3-core sheathed wire input, in which the brown wire is connected to the live wire, the blue wire is connected to the neutral wire, and the yellow-green flower wire is connected to the earth wire.

Fix the LED flood light on the installation platform, tighten the hexagonal screws, and keep the balance of the LED high pole light during installation.

LED flood light can work normally with rated voltage. In the process of working, the voltage must be within the rated range. Beyond the rated voltage, it will cause irreparable damage.

2.Precautions

Please cut off the power supply before installation and ensure that the installation part can bear the weight of the light.

In order to prevent falling off, please make sure the installation is correct.

Please do not cover the light with any stuff.

For safety, please make sure the earth wire is connected.

Breakdowns caused by decomposition, modification, or improper construction of the product are not covered by this warranty.

 